header_left logo header_right
Home Company Information Services & Technology Quality News & Events Investor Information Customer Login Contact Information
tech_left Technology Center
     
Services & Technology design engineering Test Engineering
Prototype

IEC performs in-circuit and functional testing for production assemblies, as well as flying probe testing for quick-turn projects. Our capabilities also include Environmental Stress Screening with our ESS ovens.

PCP Assembly  
Box Build  
Test Engineering

 

In-circuit test of 
telecom equipment
Functional test of 
computer peripheral equipment

 
Environmental Stress Screening of PCB's for transportation industry
In-circuit test of PCB's on
 production line
Material Management
Program Management  
Advanced Materials Lab  
chip_board
 
 

IEC's test engineers are also experienced in RF. Previous projects have included satellite TV receivers in L-Band (DSS predecessor), wireless LAN based devices with GPS, CATV components, direct digital synthesizers of up to 8 Ghz and flextags used in measuring shipment efficiency. Test equipment utilized for RF projects include network analyzers, S-parameter test sets, spectrum analyzers, signal generators and transmission analyzers. IEC gives our customers a "Design for Testability Review". The goal of this checklist is to provide: the ability to electrically isolate during ICT; an electrically stable environment; and a high percentage of access for bed-of-nails.


In-circuit test capabilities

  • Flying probe test
    • GenRad Pilot (NY Technology Center)
  • In-circuit test
    • GenRad 228X, TS128L (7100 points)
    • Teradyne 1880, 1890
Functional test capabilities
  • Usually mock-up
    • Simulates end product
    • Customer supplied
  • PC controlled (IEC developed or CFE)
    • IEEE-488 interface
    • VXI interface
    • PXI interface
Environmental Stress Screening (ESS Oven) capabilities
  • ESPEC ESS85-10JW
    • Interior volume 85 cu. ft.
    • Temperature range -200 C to 800C
    • Temperature ramp per minute 150 C
    • Comm. interfaces RS-232, IEEE-488
    • Compressors 2x30 hp
    • Heaters 150kW
    • Blowers 2x10 hp
    • Full load amps 316
  • ESPEC ESS37-5JWC
    • Interior volume 37 cu. ft.
    • Temperature range -600 C to 1770C
    • Temperature ramp per minute 100 C
    • Comm. interfaces RS-232, IEEE-488
    • Compressors 2x30 hp and 1x10 hp
    • Heaters 55kW
    • Blowers 2 x 10 hp<
  • ESPEC ET34-10JW
    • Interior volume 34 cu. ft.
    • Temperature range -200 C to 1770C
    • Temperature ramp per minute 150 C
    • Comm. interfaces RS-232, IEEE-488
    • Compressors 2 x 30 hp
    • Heaters 50kW
    • Blowers 2x10 hp
    • Full load amps 110
  • Tenney T30RC
    • Interior volume 30 cu. ft.
    • Temperature range -550 C to 1250C
    • Temperature ramp per minute 30 C
    • Comm. interfaces RS-232
    • Compressors 1x10hp
    • Heaters 5kW
    • Blowers 1x3 hp
    • Full load amps 
  • Blue M POM7-16BI-E/F
    • Interior volume 36 cu. ft.
    • Temperature range +300 C to 2000C
    • Heaters 5kW
    • Blowers 1x3 hp
  • Blue M BTC80-EMPX-155
    • Interior volume 80 cu. ft.
    • Temperature range +300 C to 2000C
    • Heaters 21kW
    • Blowers 2x3 hp
  • Thermodynamics Engineering 8219
    • Interior volume 600 cu. ft.
    • Temperature range +300 C to 2000C
    • Heaters6kW